Access to product detection data and quality verification information, supporting project acceptance and technical assessment.
Key data for testing reports
The following is a summary of key data from the original test report, with values, conditions and phenomena from the report No. TL26080414. Application is used to support understanding indicators and does not replace complete detection reports and specific engineering designs.
Report number No. TL26080414
18.91 MPaTensile strength
469%Elongation at break
0.3 MPaNo water leakage for 120 min
3.88 MPaBond strength, substrate failure
Six key capabilities.
Each indicator corresponds to the sample, test conditions and report number, facilitating technical communication and validation of project information.
01
Tensile properties and crack resistance
18.91 MPa / 469%
Testing items
tensile strength / elongation at break
Indicator requirements
≥10 MPa / ≥300%
Results
18.91 MPa / 469%, this conclusion corresponds
Meaning of applicationA balance between intensity and dilation helps to adapt the coating to substrate changes.
02
Water impermeability
0.3 MPa · 120 min
Testing items
Water impermeability
Test conditions
0.3 MPa, continuous 120 min
Results
No water seepage, this conclusion is consistent
Meaning of applicationUsed to assess membrane containment and resistance.
03
Bond strength
3.88 MPa
Testing items
Bond strength under the specified test conditions
Indicator requirements
≥2.5 MPa or base damage
Results
3.88 MPa, base material destruction, this conclusion is consistent
Meaning of applicationThe coatings are shown to be more adhesive to the test base.
04
Water resistance
23℃ · 14 d
Testing items
Water resistance
Test conditions
23℃, impregnated 14 d
Results
No cracks, no layers, no sticky hair, no bubbles, no cracks.
Meaning of applicationFor assessment of membrane stability in a continuous water environment.
05
Temperature bends
- 35℃ without crack
Testing items
Temperature bends
Indicator requirements
- 35℃, no crack
Results
- 35℃, non-fissile, this conclusion meets
Meaning of applicationIt is used to assess flex and fracking performances in low-temperature conditions.